Clock Thermostat ICD3

Clock Thermostat ICD3

4-event clock thermostat - with one sensor

Electronic thermostat for control of temperature by means of a sensor placed either externally in the floor or built into the thermostat. ICD3 can also operate in regulator mode, for renovation purposes where a floor sensor can not be used.

The thermostat has a built-in clock - calendar with power backup and comes with built-in 4-event program for automatic comfort and setback temperature. The graphical display has an unique user interface with new graphical menus and button-based navigation for easy programming and readout of data.

  • Easy menu navigation and programming in 5 different languages
  • Adaptive control ensuring comfort temperature at the required time
  • Built-in clock function for automatic comfort and setback temperatures
  • Built-in schedule ready for use. Delivered with factory-set program
  • Thin clock thermostat, giving the installer an easier job
  • Graphical backlit display for ease of use
FAQ
  • What is the maximum length of the sensor cable?

    Reply

    In general, we recommend a maximum cable length of 50 meters, the length might be shorter. Read the instructions for the precise maximum length.

  • Where to connect the ground wire of floor mats?

    Reply

    The ground wire in the floor mat must be connected directly to the ground wire of the supply.

  • What is the recommended night setback?

    Reply

    The recommended night setback is max 5°C/41°F

     

     

  • Does the adaptive function reset when making a factory reset?

    Reply

    Yes the adaptive function is reset during a factory reset.

     

     

  • How can I cure the E2 error message?

    Reply

    "E2" means defective, damaged or disconnected floor sensor. Sensor resistance should be 10 or 12 kOhm at 25°C (77°F). The onstruction or quick guide holds informatiom for the specific thermostats.